Skip to content
Tracked Standard Shipping On All Orders I Call Us on 866.802.7613 I Chat with USA Based Agents I Email Customerservice@meubon.com
Tracked Standard Shipping On All Orders I Call Us on 866.802.7613 I Chat with USA Based Agents I Email Customerservice@meubon.com

Country

High Performance Chromatograph: Insulating Transformer Oil Analysis System with Dissolved Gas Analyzer | Accurate Monitoring & Analysis for Transformer Maintenance

by MEUBON
Save 8% Save 8%
Original price $37,960.00
Original price $37,960.00 - Original price $37,960.00
Original price $37,960.00
Current price $35,000.00
$35,000.00 - $35,000.00
Current price $35,000.00

Experience unparalleled efficiency and accuracy with our High Performance Chromatograph Insulating Transformer Oil Analysis System featuring a Dissolved Gas Analyzer.

Explore its advanced features:

  1. Effortless Connectivity: Utilizes a cutting-edge 10/100m adaptive Ethernet communication interface and built-in IP protocol stack for seamless long-distance data transmission over enterprise Intranet and Internet, simplifying laboratory setup and analysis data management.

  2. Real-time Monitoring: Three separate connections enable local processing site, unit director, and supervisor to monitor instrument operation and analysis data in real-time, enhancing supervision and control.

  3. Multi-Chromatograph Support: NetChromTM workstation supports multiple chromatographs simultaneously, streamlining data processing, control, and document management to reduce laboratory investment and operating costs.

  4. User-Friendly Interface: Offers operating systems in Chinese and English, allowing users to switch as needed for convenience.

  5. Customizable Temperature Control: Users can freely name temperature control areas for ease of use.

  6. Robust Performance: Features multi-processor parallel operation for stability and reliability, accommodating complex sample analysis with up to four detectors, including FID, TCD, ECD, FPD, and NPD.

  7. Modular Design: Modular structure facilitates easy replacement and upgrade, safeguarding investment effectiveness.

  8. Precision Temperature Control: Incorporates a new microcomputer temperature control system with high accuracy and reliability, featuring a six-way independent temperature control system for versatile sample analysis.

  9. Digital Control Enhancements: Can be paired with advanced electronic flow controller (EFC) and electronic pressure controller (EPC) for improved reproducibility of qualitative and quantitative results.

  10. Programmable Operation: Designed with timing and self-starting program for seamless online gas sample analysis with an optional on-line automatic sample injection unit.

  11. User-Friendly Operation: Simple keyboard-controlled microcomputer interface with automatic detector identification, fault diagnosis, and power-off data protection for hassle-free operation.

  12. High-Resolution Signal Processing: Equipped with built-in low noise, high resolution 24-bit AD circuit with baseline storage and deduction functionality.

  13. Compatibility: Supports Windows XP, Windows 2000, Windows 7, and other operating systems, storing sample data in CDF files compatible with leading chromatography workstations.

  14. Versatile Connectivity: Features MODBUS/TCP standard interface for easy integration with Distributed Control Systems (DCS) and other external systems.

  15. Wide Compatibility: Compatible with automatic injectors from various manufacturers for enhanced flexibility and convenience in sample handling.

Specifications

  • Operating Display: 192×64 lattice sinicized liquid crystal
  • Temperature Control Domain: 6 routes
  • Temperature Range: Indoor temperature +5℃ to 400℃, increment: 1℃, Precision: ±0.1℃
  • Temperature Program Order: 16 steps
  • Heating Rate: 0.1 to 40℃/min
  • Pneumatic Control: Mechanical valve control mode, electronic pressure flow control mode, any optional
  • External Events: 4 routes
  • Sample Injector Species: Fill column, capillary, six-way valve gas injection, automatic headspace injection, etc., optional
  • Detection Configured: 5 Entries (FID, TCD, ECD, FPD, NPD optional)
  • Sample Start: Manual or self-motion, any selection
  • Communication Port: Ethernet: IEEE802.3
  • Gross Weight of the Host: 59kg
  • Host Volume: 706065cm^3
  • Oscillation Device:
    • Gross Weight: 88lbs
    • Volume: 614657cm^3
  • Air Gas Generator:
    • Gross Weight: 88lbs
    • Volume: 654077cm^3
  • Hydrogen Generator:
    • Gross Weight: 46lbs
    • Volume: 533655cm^3
  • Gas Cylinders:
    • Gross Weight: 38lbs
    • Volume: 9621.521.5cm^3

Unlock the full potential of chromatographic analysis with our state-of-the-art system designed for precision and reliability.

  • Warranty : 1 Year
  • Display : 192*64 LCD
  • Temperature Control Area : 6 Loops
  • Temperature Control Range : Room Temperature: +5~400
  • Programmed Temperature Order : 16
  • External : 4 Loops
  • Number of Detectors : >40db
  • dimension : Fid, Tcd, Ecd, Fpd, Npd (Optional)
  • Start Sampling : Manual, Auto