Introducing our advanced Digital Mammography System, designed to revolutionize breast examinations with cutting-edge technology and precise specifications:
- High Voltage Generator Type: Operates with a high-frequency inverter design for optimal performance.
- X-ray Tube Voltage: Adjustable within the range of 20-40kV (in 0.5kV increments), providing versatile settings for varied examinations.
- X-ray Tube Current: Ranges from 10mA to 160mA, ensuring accurate imaging with customizable intensity.
- Maximum Output Power: Offers a maximum power of 5kW (40kV, 125mA), guaranteeing efficient operation even at high settings.
- Radiograph Time: Adjustable from 0.005 to 10 seconds, facilitating swift yet detailed scans.
- mAs Range: From 0.5mAs to 560mAs, providing flexibility in exposure control for diverse patient needs.
- Exposure Control Modes: Equipped with manual, semi-automatic, and automatic modes for user convenience.
- Radiating Mode: Features cross-ventilation for enhanced safety and consistent performance.
- X-ray Tube: Utilizes the XM15 HMT-113 tube with options for small and big focus sizes (0.1mm/0.3mm), ensuring precision in imaging.
- Anode Heat Capacity: With a maximum capacity of 225kJ (300kHU), suitable for intensive usage in clinical settings.
- Anode Cooling: Utilizes efficient oil cooling mechanisms to maintain optimal operating temperatures.
- Radiation Field and Filtration: Offers a broad radiation field (18cm-50cm) with inherent (0.5mmBe) and additional (0.03mmMo) filtration for enhanced safety and image quality.
- Anode Speed: Adjustable between low-speed (3000r/min) and high-speed (10000r/min) settings for versatile imaging requirements.
- C Arm Frame: Provides extensive vertical and rotational ranges of motion for optimal positioning during examinations.
- FPD (Flat Panel Detector): Features high-resolution imaging capabilities (2816*3584 pixels) with a pixel size of 85um and ≥16bit grayscale depth for detailed and accurate results.
- Collimator: Equipped with precise collimation options and filtration for targeted imaging and reduced radiation exposure.
- Image Acquisition Workstation: Offers a comprehensive workstation with a large screen (19"), ample memory (≥8G), and DICOM compatibility for seamless integration with hospital systems.
- Integrated Design: Boasts an integrated design with the high-voltage generator, streamlining workflow and simplifying operation.
Our Digital Mammography System combines precision, efficiency, and safety, making it an indispensable tool for modern breast examinations in medical facilities.
![](http://sc04.alicdn.com/kf/H7f11adf88fc34ac095a892af5eaaa8bfE/238255025/H7f11adf88fc34ac095a892af5eaaa8bfE.jpg)
![](http://sc04.alicdn.com/kf/H0cfc725b9bb7427d809789ca45a155c3X/238255025/H0cfc725b9bb7427d809789ca45a155c3X.jpg)
![](http://sc04.alicdn.com/kf/Ha5b1a387048444988b04810096314129Q/238255025/Ha5b1a387048444988b04810096314129Q.jpg)
![](http://sc04.alicdn.com/kf/H62160c1a9a924a33ab134d4d390253a6w/238255025/H62160c1a9a924a33ab134d4d390253a6w.jpg)
![](http://sc04.alicdn.com/kf/Hf13da1cad6b34360912c6c4427748f12v/238255025/Hf13da1cad6b34360912c6c4427748f12v.jpg)
![](http://sc04.alicdn.com/kf/Ha63b2df66a494eb89936ed4101a9d680n/238255025/Ha63b2df66a494eb89936ed4101a9d680n.jpg)
![](http://sc04.alicdn.com/kf/Hfa2f84b5149d4964a8f9b0b86ae4209bl/238255025/Hfa2f84b5149d4964a8f9b0b86ae4209bl.jpg)
![](http://sc04.alicdn.com/kf/H3dff7e3835aa4b62bb3931a69255fa65j/238255025/H3dff7e3835aa4b62bb3931a69255fa65j.jpg)
Specifications
Digital Mammography System
|
|||
High voltage generator
|
Type
|
High frequency inverter type
|
|
X-ray tube voltage
|
20-40kV(step 0.5kV)
|
||
X-ray tube current
|
10mA-160mA
|
||
Maximum output power
|
5kW(40kV,125mA)
|
||
Nominal power
|
4.8kW(30kV,160mA,0.1s)
|
||
Radiograph time
|
0.005-10s
|
||
mAs
|
0.5mAS~560mAs
|
||
Minimum mAs
|
0.5mAs(50ms 10mA)
|
||
Maximun mAs
|
560mAs
|
||
Minimum mAs in AEC
|
6.3mAs
|
||
Exposure control
|
manual ,semi-auto,auto
|
||
Radiating mode
|
cross-ventilation
|
||
X-ray tube
|
|
XM15
|
HMT-113
|
|
small focus/big focus
|
small focus/big focus
|
|
Focus size
|
0.1mm/0.3mm
|
0.1mm/0.3mm
|
|
Maximum anode heat capacity
|
225kJ(300kHU)
|
225kJ(300kHU)
|
|
Maximum heat dissipation
|
500W
|
500W
|
|
Anode cooling mode
|
oil cooling
|
oil cooling
|
|
Nominal voltage
|
40kV
|
40kV
|
|
Target angle
|
15°
|
10°/16°
|
|
Target material
|
Mo
|
Mo
|
|
Radiation field
|
18cm-50cm
|
18cm-50cm
|
|
Inherent filtration
|
0.5mmBe
|
0.5mmBe
|
|
Additional filtration
|
0.03mmMo
|
/
|
|
Anode speed
|
low-speed3000r/min; high-speed 10000r/min
|
low-speed3000r/min; high-speed 10000r/min
|
|
Anode input power
|
1.15-2KW / 4.8-9kW
|
0.7-1.35kW / 2.9-4.9kW
|
|
X-ray tube socket (C339v)
|
|
|
|
Additional filtration
|
0.03mmMo
|
||
Weight
|
13kg
|
||
C Arm frame
|
|
|
|
vertical range of motion
|
630-1400mm,deviation±5%
|
||
Rotation range of motion
|
+195°~-155°Angular division value 1°,deviation±2%
|
||
FID
|
660mm,deviation±5%
|
||
3D tomographic axial rotation
|
+30°~-30°deviation±2%
|
||
Rotate Mode
|
power-drive double speed rotate
|
||
|
Preset angle and memory function
|
||
Oppression plate
|
range of motion
|
245mm,deviation±10%
|
|
range of motion in 1.5 times platfo
|
150mm,deviation±10%
|
||
range of motion in 1.8 times platfo
|
75mm,deviation±10%
|
||
Operation mode
|
Manual/Auto
|
||
Pressure range
|
0-300N(Manual)150-200N(Auto)
|
||
FPD
|
|
AXS-2430
|
HMD-2430
|
Pixel unit
|
85um
|
85um
|
|
Effective pixel size
|
239.36*304.64mm
|
239.36*304.64mm
|
|
Pixel matirx
|
2816*3584 pixels
|
2816*3584 pixels
|
|
Spatial resolution
|
≥7 lp/mm
|
≥7 lp/mm
|
|
Cooling mode
|
fan cooling
|
fan cooling
|
|
Grayscale
|
≥16bit
|
≥16bit
|
|
DQE
|
≥50%
|
≥50%
|
|
Grid
|
|
|
|
Grid proportion
|
5:1
|
||
Size
|
338*264mm
|
||
line pair
|
36lp/cm
|
||
focus
|
66cm
|
||
Collimator (HMC-915)
|
|
|
|
Power supply
|
24V DC,2A
|
||
Radiation field
|
Min 5*5cm/Max 24*30cm
|
||
Radiograph platform
|
Field 24*30cm SID 660mm,deviation±5%
|
||
1.5 times radiograph platform
|
Field 16*20cm SID 440mm,deviation±5%
|
||
1.8 times radiograph platform
|
Field 13.6*16.7cm SID 366.7mm,deviation±5%
|
Collimator (HMC-915)
|
Inherent filtration
|
0.02mmAl
|
Additional filtration
|
0.03mmMo /0.025Rh
|
|
Illumination in max SID
|
>160Lux
|
|
Timer
|
Button/Auto,30s timer
|
|
Indicator light
|
LED
|
|
maximum radiation leakage
|
<40mRh
|
|
Light field switch
|
Auto
|
|
Weight
|
3.6kg
|
|
Image Acquisition Workstat
|
Screen size/resolution
|
19",Resolution 1280*1024,Contrat 1000:1
|
Memory
|
≥8G
|
|
Hard disk
|
≥320G
|
|
OS
|
Win7
|
|
Image format
|
DICOM3.0(can connect with RIS)
|
|
Image storage capacity
|
≥20000 images
|
|
|
mamual input patients' date or download form HIS/RIS through DICOM Worklist
|
|
|
CD-R writer (storage image)
|
|
|
Choosing Breast implants Function
|
|
|
Integrated design with High voltage generator, exposure specification setting in workstation
|
- Power Requirement : One-Phase single phase 220V±20V AC
- Mains Frequency : 50Hz/60Hz
- Max Power : 5KW
- Standard Power : 4.8Kw
- Ma Range : 10~200mA
- MAS Range : 0.1~630mAS
- KV Range : 20~40KV
- Sample : Avaliable