Advanced Digital Mammography Machine for High-Frequency Breast Examinations - Hospital-Grade X-Ray Mamografo
by MEUBON
Save 11%
Original price
$145,089.00
Original price
$145,089.00
-
Original price
$145,089.00
Original price
$145,089.00
Current price
$129,500.00
$129,500.00
-
$129,500.00
Current price
$129,500.00
Introducing our advanced Digital Mammography System, designed to revolutionize breast examinations with cutting-edge technology and precise specifications:
- High Voltage Generator Type: Operates with a high-frequency inverter design for optimal performance.
- X-ray Tube Voltage: Adjustable within the range of 20-40kV (in 0.5kV increments), providing versatile settings for varied examinations.
- X-ray Tube Current: Ranges from 10mA to 160mA, ensuring accurate imaging with customizable intensity.
- Maximum Output Power: Offers a maximum power of 5kW (40kV, 125mA), guaranteeing efficient operation even at high settings.
- Radiograph Time: Adjustable from 0.005 to 10 seconds, facilitating swift yet detailed scans.
- mAs Range: From 0.5mAs to 560mAs, providing flexibility in exposure control for diverse patient needs.
- Exposure Control Modes: Equipped with manual, semi-automatic, and automatic modes for user convenience.
- Radiating Mode: Features cross-ventilation for enhanced safety and consistent performance.
- X-ray Tube: Utilizes the XM15 HMT-113 tube with options for small and big focus sizes (0.1mm/0.3mm), ensuring precision in imaging.
- Anode Heat Capacity: With a maximum capacity of 225kJ (300kHU), suitable for intensive usage in clinical settings.
- Anode Cooling: Utilizes efficient oil cooling mechanisms to maintain optimal operating temperatures.
- Radiation Field and Filtration: Offers a broad radiation field (18cm-50cm) with inherent (0.5mmBe) and additional (0.03mmMo) filtration for enhanced safety and image quality.
- Anode Speed: Adjustable between low-speed (3000r/min) and high-speed (10000r/min) settings for versatile imaging requirements.
- C Arm Frame: Provides extensive vertical and rotational ranges of motion for optimal positioning during examinations.
- FPD (Flat Panel Detector): Features high-resolution imaging capabilities (2816*3584 pixels) with a pixel size of 85um and ≥16bit grayscale depth for detailed and accurate results.
- Collimator: Equipped with precise collimation options and filtration for targeted imaging and reduced radiation exposure.
- Image Acquisition Workstation: Offers a comprehensive workstation with a large screen (19"), ample memory (≥8G), and DICOM compatibility for seamless integration with hospital systems.
- Integrated Design: Boasts an integrated design with the high-voltage generator, streamlining workflow and simplifying operation.
Our Digital Mammography System combines precision, efficiency, and safety, making it an indispensable tool for modern breast examinations in medical facilities.
Specifications
Digital Mammography System
|
|||
High voltage generator
|
Type
|
High frequency inverter type
|
|
X-ray tube voltage
|
20-40kV(step 0.5kV)
|
||
X-ray tube current
|
10mA-160mA
|
||
Maximum output power
|
5kW(40kV,125mA)
|
||
Nominal power
|
4.8kW(30kV,160mA,0.1s)
|
||
Radiograph time
|
0.005-10s
|
||
mAs
|
0.5mAS~560mAs
|
||
Minimum mAs
|
0.5mAs(50ms 10mA)
|
||
Maximun mAs
|
560mAs
|
||
Minimum mAs in AEC
|
6.3mAs
|
||
Exposure control
|
manual ,semi-auto,auto
|
||
Radiating mode
|
cross-ventilation
|
||
X-ray tube
|
|
XM15
|
HMT-113
|
|
small focus/big focus
|
small focus/big focus
|
|
Focus size
|
0.1mm/0.3mm
|
0.1mm/0.3mm
|
|
Maximum anode heat capacity
|
225kJ(300kHU)
|
225kJ(300kHU)
|
|
Maximum heat dissipation
|
500W
|
500W
|
|
Anode cooling mode
|
oil cooling
|
oil cooling
|
|
Nominal voltage
|
40kV
|
40kV
|
|
Target angle
|
15°
|
10°/16°
|
|
Target material
|
Mo
|
Mo
|
|
Radiation field
|
18cm-50cm
|
18cm-50cm
|
|
Inherent filtration
|
0.5mmBe
|
0.5mmBe
|
|
Additional filtration
|
0.03mmMo
|
/
|
|
Anode speed
|
low-speed3000r/min; high-speed 10000r/min
|
low-speed3000r/min; high-speed 10000r/min
|
|
Anode input power
|
1.15-2KW / 4.8-9kW
|
0.7-1.35kW / 2.9-4.9kW
|
|
X-ray tube socket (C339v)
|
|
|
|
Additional filtration
|
0.03mmMo
|
||
Weight
|
13kg
|
||
C Arm frame
|
|
|
|
vertical range of motion
|
630-1400mm,deviation±5%
|
||
Rotation range of motion
|
+195°~-155°Angular division value 1°,deviation±2%
|
||
FID
|
660mm,deviation±5%
|
||
3D tomographic axial rotation
|
+30°~-30°deviation±2%
|
||
Rotate Mode
|
power-drive double speed rotate
|
||
|
Preset angle and memory function
|
||
Oppression plate
|
range of motion
|
245mm,deviation±10%
|
|
range of motion in 1.5 times platfo
|
150mm,deviation±10%
|
||
range of motion in 1.8 times platfo
|
75mm,deviation±10%
|
||
Operation mode
|
Manual/Auto
|
||
Pressure range
|
0-300N(Manual)150-200N(Auto)
|
||
FPD
|
|
AXS-2430
|
HMD-2430
|
Pixel unit
|
85um
|
85um
|
|
Effective pixel size
|
239.36*304.64mm
|
239.36*304.64mm
|
|
Pixel matirx
|
2816*3584 pixels
|
2816*3584 pixels
|
|
Spatial resolution
|
≥7 lp/mm
|
≥7 lp/mm
|
|
Cooling mode
|
fan cooling
|
fan cooling
|
|
Grayscale
|
≥16bit
|
≥16bit
|
|
DQE
|
≥50%
|
≥50%
|
|
Grid
|
|
|
|
Grid proportion
|
5:1
|
||
Size
|
338*264mm
|
||
line pair
|
36lp/cm
|
||
focus
|
66cm
|
||
Collimator (HMC-915)
|
|
|
|
Power supply
|
24V DC,2A
|
||
Radiation field
|
Min 5*5cm/Max 24*30cm
|
||
Radiograph platform
|
Field 24*30cm SID 660mm,deviation±5%
|
||
1.5 times radiograph platform
|
Field 16*20cm SID 440mm,deviation±5%
|
||
1.8 times radiograph platform
|
Field 13.6*16.7cm SID 366.7mm,deviation±5%
|
Collimator (HMC-915)
|
Inherent filtration
|
0.02mmAl
|
Additional filtration
|
0.03mmMo /0.025Rh
|
|
Illumination in max SID
|
>160Lux
|
|
Timer
|
Button/Auto,30s timer
|
|
Indicator light
|
LED
|
|
maximum radiation leakage
|
<40mRh
|
|
Light field switch
|
Auto
|
|
Weight
|
3.6kg
|
|
Image Acquisition Workstat
|
Screen size/resolution
|
19",Resolution 1280*1024,Contrat 1000:1
|
Memory
|
≥8G
|
|
Hard disk
|
≥320G
|
|
OS
|
Win7
|
|
Image format
|
DICOM3.0(can connect with RIS)
|
|
Image storage capacity
|
≥20000 images
|
|
|
mamual input patients' date or download form HIS/RIS through DICOM Worklist
|
|
|
CD-R writer (storage image)
|
|
|
Choosing Breast implants Function
|
|
|
Integrated design with High voltage generator, exposure specification setting in workstation
|
- Power Requirement : One-Phase single phase 220V±20V AC
- Mains Frequency : 50Hz/60Hz
- Max Power : 5KW
- Standard Power : 4.8Kw
- Ma Range : 10~200mA
- MAS Range : 0.1~630mAS
- KV Range : 20~40KV
- Sample : Avaliable