{"product_id":"corneal-topographer-surface-curvature-mapping-for-eye-labs-optometry-clinics-ophthalmic-corneal-analysis-system","title":"Corneal Topographer – Surface Curvature Mapping for Eye Labs \u0026 Optometry Clinics | Ophthalmic Corneal Analysis System","description":"\u003cp data-start=\"126\" data-end=\"232\"\u003e\u003cstrong data-start=\"126\" data-end=\"232\"\u003eCorneal Topographer – Surface Curvature Analysis System for Ophthalmic Labs, Optometry \u0026amp; Ophthalmology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"260\" data-end=\"633\"\u003eThe \u003cstrong data-start=\"264\" data-end=\"287\"\u003eCorneal Topographer\u003c\/strong\u003e is a high-precision diagnostic device designed for detailed \u003cstrong data-start=\"348\" data-end=\"405\"\u003emapping and analysis of the corneal surface curvature\u003c\/strong\u003e. Utilizing \u003cstrong data-start=\"417\" data-end=\"487\"\u003ePLACIDO cone technology with 31 rings and 7,936 measurement points\u003c\/strong\u003e, this system delivers comprehensive visualizations that support clinical decision-making in \u003cstrong data-start=\"580\" data-end=\"632\"\u003eophthalmology, optometry, and refractive surgery\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"635\" data-end=\"894\"\u003eIdeal for \u003cstrong data-start=\"645\" data-end=\"730\"\u003epreoperative evaluation, postoperative outcome analysis, and contact lens fitting\u003c\/strong\u003e, the system provides a range of detailed maps including \u003cstrong data-start=\"787\" data-end=\"854\"\u003eaxial curvature, tangential curvature, elevation, 3D topography\u003c\/strong\u003e, and \u003cstrong data-start=\"860\" data-end=\"893\"\u003esimulated keratoscope imaging\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"635\" data-end=\"894\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0584\/9330\/5037\/files\/H54f673d44b4449cc85e5bdec55a6f02cD_dd8fb016-3895-4b2f-85b0-fd1b7cb2dbf3.webp?v=1748742680\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"icbu-pc-detailManyImage magic-4\"\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/H53dc66db38f542d185e297cae87e768dq\/236934233\/H53dc66db38f542d185e297cae87e768dq.jpg\" src=\"https:\/\/sc04.alicdn.com\/kf\/H53dc66db38f542d185e297cae87e768dq\/236934233\/H53dc66db38f542d185e297cae87e768dq.jpg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/Hee95f63e60874f339f85593a26df4676y\/236934233\/Hee95f63e60874f339f85593a26df4676y.jpg\" src=\"https:\/\/sc04.alicdn.com\/kf\/Hee95f63e60874f339f85593a26df4676y\/236934233\/Hee95f63e60874f339f85593a26df4676y.jpg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/Hc9d833ba133a4d81805d48828c4e22b7s\/236934233\/Hc9d833ba133a4d81805d48828c4e22b7s.png\" src=\"https:\/\/sc04.alicdn.com\/kf\/Hc9d833ba133a4d81805d48828c4e22b7s\/236934233\/Hc9d833ba133a4d81805d48828c4e22b7s.png\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/Hd16f06f713ce4a89a9651d51ad953143C\/236934233\/Hd16f06f713ce4a89a9651d51ad953143C.png\" src=\"https:\/\/sc04.alicdn.com\/kf\/Hd16f06f713ce4a89a9651d51ad953143C\/236934233\/Hd16f06f713ce4a89a9651d51ad953143C.png\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/Ha8f1405aa588499ab86a440a91307548f\/236934233\/Ha8f1405aa588499ab86a440a91307548f.png\" src=\"https:\/\/sc04.alicdn.com\/kf\/Ha8f1405aa588499ab86a440a91307548f\/236934233\/Ha8f1405aa588499ab86a440a91307548f.png\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"magic-5\"\u003e\u003cimg data-spm-anchor-id=\"a2700.details-description.0.i1.513e22Uy22Uy1t\" class=\"magic-6\" data-src=\"\/\/sc04.alicdn.com\/kf\/H5bd4e14bc189486f90b5737738cb065cY\/236934233\/H5bd4e14bc189486f90b5737738cb065cY.jpg\" src=\"https:\/\/sc04.alicdn.com\/kf\/H5bd4e14bc189486f90b5737738cb065cY\/236934233\/H5bd4e14bc189486f90b5737738cb065cY.jpg\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv data-spm-anchor-id=\"a2700.details-description.0.i2.513e22Uy22Uy1t\" class=\"magic-3\" data-section-title=\"Specification\" data-section=\"AliMagic-c4baro\" id=\"ali-anchor-AliMagic-c4baro\"\u003eSpecification\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"896\" data-end=\"899\"\u003e\n\u003ch3 data-start=\"901\" data-end=\"925\"\u003e🔍 \u003cstrong data-start=\"908\" data-end=\"925\"\u003eKey Features:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"927\" data-end=\"1613\"\u003e\n\u003cli data-start=\"927\" data-end=\"976\"\u003e\n\u003cp data-start=\"929\" data-end=\"976\"\u003e\u003cstrong data-start=\"929\" data-end=\"950\"\u003eMeasurement Mode:\u003c\/strong\u003e PLACIDO Cone Technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"977\" data-end=\"1034\"\u003e\n\u003cp data-start=\"979\" data-end=\"1034\"\u003e\u003cstrong data-start=\"979\" data-end=\"1004\"\u003eMeasurement Coverage:\u003c\/strong\u003e Diameter up to \u003cstrong data-start=\"1020\" data-end=\"1032\"\u003e10.91 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1035\" data-end=\"1105\"\u003e\n\u003cp data-start=\"1037\" data-end=\"1105\"\u003e\u003cstrong data-start=\"1037\" data-end=\"1064\"\u003eCurvature Radius Range:\u003c\/strong\u003e \u003cstrong data-start=\"1065\" data-end=\"1085\"\u003e5.5 mm – 10.0 mm\u003c\/strong\u003e (33.75D – 61.36D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1106\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1149\"\u003e\u003cstrong data-start=\"1108\" data-end=\"1134\"\u003eMeasurement Precision:\u003c\/strong\u003e \u003cstrong data-start=\"1135\" data-end=\"1147\"\u003e±0.02 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1202\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1202\"\u003e\u003cstrong data-start=\"1152\" data-end=\"1170\"\u003ePlacido Rings:\u003c\/strong\u003e 31 precision-calibrated rings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1203\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1205\" data-end=\"1263\"\u003e\u003cstrong data-start=\"1205\" data-end=\"1234\"\u003eTotal Measurement Points:\u003c\/strong\u003e 7,936 for detailed mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1433\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1292\"\u003e\u003cstrong data-start=\"1266\" data-end=\"1290\"\u003eMap Display Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1295\" data-end=\"1433\"\u003e\n\u003cli data-start=\"1295\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1297\" data-end=\"1318\"\u003eAxial Curvature Map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1321\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1323\" data-end=\"1349\"\u003eTangential Curvature Map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1352\" data-end=\"1369\"\u003e\n\u003cp data-start=\"1354\" data-end=\"1369\"\u003eElevation Map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1372\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1374\" data-end=\"1401\"\u003eSimulated Keratoscope Map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1404\" data-end=\"1433\"\u003e\n\u003cp data-start=\"1406\" data-end=\"1433\"\u003e3D Corneal Topography Map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1434\" data-end=\"1486\"\u003e\n\u003cp data-start=\"1436\" data-end=\"1486\"\u003e\u003cstrong data-start=\"1436\" data-end=\"1447\"\u003eOutput:\u003c\/strong\u003e High-resolution color inkjet printer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1487\" data-end=\"1613\"\u003e\n\u003cp data-start=\"1489\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1489\" data-end=\"1510\"\u003eAdjustable Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1515\" data-end=\"1613\"\u003e\n\u003cli data-start=\"1515\" data-end=\"1537\"\u003e\n\u003cp data-start=\"1517\" data-end=\"1537\"\u003eLeft\/Right: \u0026gt;86 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1540\" data-end=\"1568\"\u003e\n\u003cp data-start=\"1542\" data-end=\"1568\"\u003eForward\/Backward: \u0026gt;40 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1590\"\u003e\n\u003cp data-start=\"1573\" data-end=\"1590\"\u003eUp\/Down: \u0026gt;30 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1613\"\u003e\n\u003cp data-start=\"1595\" data-end=\"1613\"\u003eChinrest: \u0026gt;50 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1615\" data-end=\"1618\"\u003e\n\u003ch3 data-start=\"1620\" data-end=\"1663\"\u003e👁️ \u003cstrong data-start=\"1628\" data-end=\"1663\"\u003eAdvanced Clinical Capabilities:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"1665\" data-end=\"1942\"\u003e\n\u003cli data-start=\"1665\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1667\" data-end=\"1747\"\u003e\u003cstrong data-start=\"1667\" data-end=\"1701\"\u003eContact Lens Fitting Guidance:\u003c\/strong\u003e Improve accuracy in adaptive lens selection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1748\" data-end=\"1847\"\u003e\n\u003cp data-start=\"1750\" data-end=\"1847\"\u003e\u003cstrong data-start=\"1750\" data-end=\"1785\"\u003eKeratoconus Detection Function:\u003c\/strong\u003e Early identification and analysis of corneal irregularities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1942\"\u003e\n\u003cp data-start=\"1850\" data-end=\"1942\"\u003e\u003cstrong data-start=\"1850\" data-end=\"1871\"\u003eSurgical Support:\u003c\/strong\u003e Pre- and post-operative assessments for corneal refractive surgeries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1944\" data-end=\"1947\"\u003e\n\u003cp data-start=\"1949\" data-end=\"2174\"\u003e\u003cstrong data-start=\"1949\" data-end=\"1966\"\u003eApplications:\u003c\/strong\u003e\u003cbr data-start=\"1966\" data-end=\"1969\"\u003ePerfect for \u003cstrong data-start=\"1981\" data-end=\"2061\"\u003eophthalmology clinics, optometry practices, eye hospitals, and research labs\u003c\/strong\u003e, this corneal analyzer ensures \u003cstrong data-start=\"2093\" data-end=\"2174\"\u003ereliable diagnostics, accurate surgical planning, and optimized patient care.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2176\" data-end=\"2257\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eUnlock precision in corneal surface mapping with this advanced topography system.\u003c\/p\u003e","brand":"Meubon","offers":[{"title":"Default Title","offer_id":48224557924557,"sku":"1600591541157","price":5700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/9330\/5037\/files\/H54f673d44b4449cc85e5bdec55a6f02cD.webp?v=1748741971","url":"https:\/\/meubon.com\/products\/corneal-topographer-surface-curvature-mapping-for-eye-labs-optometry-clinics-ophthalmic-corneal-analysis-system","provider":"Meubon","version":"1.0","type":"link"}