Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface I Model MDE5B
Features:
Comprehensive and professional dry eye examination and diagnosis program
* Support 7 ways of dry eye detection functions to provide reliable basis for clinical diagnosis.
* The test report with pictures and texts , the test results shown clearly and in detail.
* A full set of dry eye examinations can be completed in 7 minutes, effectively improving clinic efficiency.
* Non-invasive inspection method, safer operation, patient comfort and easy cooperation.
* Fully automated software analysis + Quantification of testing standards, easier diagnosis by doctors.
* Convenient patient management system, which can continuously record the development of patients.
![]() |
![]() |
Dry eye project inspection report
* Rich in content, 7 items of dry eye examination data are fully displayed on one report.
* Be clear at a glance, Sufficient image and data combination, clear and detailed display of inspection results.
* Multiple templates, Support single report, any combination of multiple projects.
TMH
* Comfortable and reliable.
* Using infrared light with a wavelength of 850μm as the light source, it will not stimulate the secretion of tears, the patient is more comfortable and the result is more reliable.
* Automatic identification, identification, measurement.
Ocular redness analysis
* Conjunctiva, sclera, two modes.
* Multi-dimensional analysis of the patient’s ocular surface hyperaemia.
* Provide more evidence for diagnosis.
* Automatic identification, analysis, and classification.
Gland Opening
* HD eyelid image.
* Can clearly obtain the overall shape of the eyelid margin.
* Image with slight changes in gland openings.
Corneal Staining
* Professional yellow filter.
* Professionally designed yellow filter.
* Make corneal fluorescein sodium stained image clearer.
* Automatic identification, analysis, classification.
NIBUT
* Comfortable and reliable: The use of infrared rays with a wavelength of 850μm will not stimulate tear secretion, and record the maintenance time of the tear film in the original state of the eye, and the result is more reliable.
* All-round: Provides first and average break-up time, tear film break-up diagram, and graph to display the situation of tear film break in all round.
Lipid layer analysis
* High precision.
* The white ring projection can completely present the true color and shape of the lipid layer.
* Automatic identification, analysis, and classification
* Using professional AI algorithm, lipid layer thickness measurement can be accurate to 10nm.
Meibomian glands imaging analysis
* Clear.
* Professional infrared imaging can clearly observe the morphology of the meibomian acini.
* AI image enhancement.
* Support automatic identification, strengthen the contrast of glands, and automatically calculate the proportion of meibomian glands missing.
- Warranty : 1 Year
- Model Number : MDE5B Dry Eye Analyzer
- TMH : yes
- NIBUT : yes
- Lipid layer analysis : yes
- Eyelid analysis : yes
- Ocular redness analysis : yes
- Meibomian gland image analysis : yes
- Staining grading analysis : yes
- Blink analysis : yes
TMH, NIBUT, Lipid layer analysis, Eyelid analysis, Ocular redness Analysis
Meibomian gland imaging analysis, Staining grading analysisBlink analysis,
Pupillary diameter measurement, Corneal diameter measurement.
![]() |
![]() |
![]() |
Specifications:
Main Functions |
|
Gland opening |
HD eyelid image |
TMH |
Optional infrared light/visible light measurement Support auomatic/manual measurement |
Ocular redness analysis |
HD eye surface image Automatic analysis and classification |
NIBUT |
Provides first and average break -up time, tear film break diagrams, and graphs, automatic analysis |
Lipid layer analysis |
Use a constant and uniform light source to detect |
Meibomian glands imaging analysis |
Acinar-level HD image Gland contrast enhancement Automatic calculation of the deficiency rate |
Staining analysis |
Professional fluoresent stain image Automatic analysis |
Gland opening |
HD eyelid image |
Functions |
DE-5A |
DE-5B |
DE-5C |
NIBUT(Non-invasive break-up time) |
Automatic |
Automatic |
Automatic |
TMH(Tear meniscus height) |
Manual |
Manual/ Automatic |
Manual/ Automatic |
LLA(Lipid layer analysis) |
Manual |
Automatic measurement can be accurate to 10nm |
Automatic measurement can be accurate to 1nm |
ORA(Ocular redness analysis) |
Manual |
Manual/ Automatic |
Manual/ Automatic |
GOA(Gland opening analysis) |
Manual |
Manual |
Manual |
MGA(Meibomian gland analysis) |
Manual |
Manual/ Automatic |
Manual/ Automatic |
CSA(Corneal staining analysis) |
Manual |
Manual/ Automatic |
Manual/ Automatic |
Questionnaire |
3 ways |
3 ways |
3 ways |
Report |
General/ Single |
General/ Single |
General/ Single |