Advanced Synchronous TGA/DTA/DSC Plastic Thermogravimetric Analysis Differential Thermal Analyzer
Product Introduction:
Our Synchronous TGA/DTA/DSC Differential Thermal Analyzer is engineered to precisely analyze temperature and heat flow, facilitating comprehensive thermogravimetric analysis of plastics. Widely utilized in polymer development, performance testing, and quality control, this analyzer offers insights into crucial parameters including glass transition temperature, melting point, cold crystallization, crystallization, phase transition, and oxidation induction time (OIT).
Unlock the potential of your plastic materials with our cutting-edge analyzer, ensuring accurate and reliable results for informed decision-making in polymer research and development.





Quality], [Operator], [Experimental Parameters], [Atmosphere], etc. The test type is selected as non-OIT according to customer
requirements, and click [Connect Instrument]. You'll hear a noise. Pay attention to the two experiments, and the sample names
cannot be the same.Otherwise, the overlay cannot be saved.

Parameter setting of oxidation induction period experiment

Parameter setting of melting point and phase transition temperature
software, the equipment will heat up according to the set program, and the software will record the data in real time.





DSC
|
BXT-DSC100L Differential scanning calorimeter
|
DSC range
|
0~±500mW
|
Temperature range
|
-10~600℃
|
Heating and cooling
|
1~100℃/min、1~20℃/min
|
Temperature resolution
|
0.001℃
|
Temperature fluctuation
|
±0.01℃
|
Temperature repeatability
|
±0.01℃
|
DSC accuracy
|
0.01mW
|
DSC sensitivity
|
0.001mW
|
Temperature control mode
|
Heating, constant temperature and cooling (program automatic control)
|
Curve scanning
|
Heating scanning, constant temperature scanning and cooling scanning
|
Atmosphere control
|
Two-way gas automatic switching
|
Display mode
|
24bit color 7-inch LCD touch screen display
|
Data interface
|
Standard USB interface
|
Instrument standard
|
With reference material (tin), the temperature and enthalpy can be calibrated by itself
|
Remarks
|
All technical indicators can be adjusted according to user needs
|
- Power : Electronic
- Temperature range : Room temperature ~1150℃
- DTA Accuracy : ± 0.1μV
- temperature resolution : ion: 0.1 ℃
- Furnace : With the lid
- Display : 24bit color 7-inch LCD touch- screen display
- Measuring range : 0 ~ ± 2000μV
- Heating rate : 1 ~ 80 ℃ / min
- Temperature control : Heating, Cooling, Thermostat
- Data interface : USB interface